4 Phase CE CQC CCC Certificates LV Low Voltage Switchgear for Data Centers
Product Description
Role of low-voltage switchgear in data centers:
- Low-voltage switchgear is a critical component of the electrical infrastructure in data centers, providing a reliable and efficient means of distributing electrical power to various loads.
- It provides a means of controlling and protecting the electrical system, ensuring that electrical energy is distributed efficiently and safely to the various loads in the data center.
Functions of low-voltage switchgear in data centers:
- Power distribution: Low-voltage switchgear is responsible for the distribution of electrical power to various loads in the data center. This includes the use of circuit breakers, fuses, and other protective devices to ensure that electrical energy is distributed safely and efficiently.
- Protection: Low-voltage switchgear is designed to protect the electrical system against electrical faults, such as overcurrents, short circuits, and earth faults. It helps to prevent damage to equipment, minimize the risk of downtime or data loss, and ensure the safety of personnel.
- Monitoring: Low-voltage switchgear can be equipped with monitoring devices that provide real-time information on the status of the electrical system, such as current, voltage, power consumption, and temperature. This information can be used to optimize the operation of the electrical system and improve energy efficiency.
- Control: Low-voltage switchgear can be used to control the operation of electrical equipment in the data center. This includes the use of contactors, relays, and other devices to start or stop motors, change the speed of fans or pumps, and switch between power sources.
- Customization: Low-voltage switchgear can be customized to meet the specific needs of each data center application. This includes the use of different types and sizes of protection devices, the configuration of circuits to meet load requirements, and the integration of communication and control interfaces.
- Integration: Low-voltage switchgear can be integrated with other components of the electrical infrastructure in the data center, such as transformers, generators, and UPSs. This helps to provide a complete and reliable power distribution system for the data center.
In summary, low-voltage switchgear plays a critical role in data centers, providing a means of distributing electrical power to various loads in the facility, protecting the equipment against electrical faults, monitoring the status of the electrical system, controlling the operation of electrical equipment, customizing the system to meet specific needs, integrating with other components of the electrical infrastructure, and improving energy efficiency. Its functions are essential for ensuring the availability, reliability, and efficiency of the electrical system in the data center.
Specification
Rated Insulation voltage | 690V (1000)V |
Rated working voltage | 380V, 400V, 690V |
Maximum working current of main bus | 6300A |
Rated withstand current of main busbar | 100kA/1s |
Main busbar rated peak withstand current | 220kA/0.1s |
Maximum operating current of branch distribution bus (vertical bus) | 2000A |
Standard type | 105kA(Max)/0.1s |
Reinforced type | 176kA(Max)/0.1s |
Protection level | IP4X, IP41,IP65 |
Why Choose Us

1.Our Expertise
2.Quality Products/Services
3.Competitive Pricing
4.Innovation
6.Possibles
7.Authorization by ABB Schneider Siemens
Engineering
1.Power generation plants
2.Substations
3.Commercial buildings
4.Data centers
5.Renewable energy systems
6.Transportation
Production Facilities