Add to Cart
Arc Insulated 1000 KVa Compact Substation for Highway and for Transportation
Product Description
• Substations come in different types - power substations step voltages down for distribution, distribution substations further step voltages down for consumers, collector substations aggregate power from generating stations, transmission substations interconnect transmission networks.
• Substations receive 3 phase power. Transformers inside step down or step up the 3 phases - A, B and C - independently.
• Circuit breakers inside a substation protect different feeders and transformers. When a fault occurs, circuit breakers detect it and instantly open to isolate the fault.
• Surge arresters protect substations from high voltage spikes and surges, directing excess voltage to ground. They mitigate damage from lightning strikes.
• Instrument transformers inside substations - current transformers and potential transformers - transform high currents and voltages into safer levels for monitoring and metering. They allow operators to monitor substation equipment performance.
• Control systems coordinate activities within a substation to ensure safe and stable power flow. They enable remote monitoring and control of substations.
• Switchgear within a substation consists of disconnect switches, circuit breakers and busbars that allow power to flow and be switched between different pieces of equipment.
• Substations undergo regular maintenance to replace faulty equipment, repair components and minimize outages. Oil insulated substation equipment requires periodic oil filtering and testing.
Specification
|
Marketing
Our business scope covers 6 continents and over 50 countries.
Material
1.The cabinet door adopts a double beveled edge process, which increases the structural strength of the same material by 50%.
2.The installation holes are all made using a multi-layer stamping and stretching process, which reduces the sliding wire situation by more than 80%.
3.The inlet and outlet holes adopt a composite structure of knockdown holes and square holes, which can be flexibly selected during on-site installation.
4.The box adopts a double folding process, which increases the structural strength of the same material by 50%.
5.The control circuit adopts a composite design of debugging mode and fire protection mode, greatly reducing the burning of fan and water pump equipment designed for fire protection during debugging.
Why Choose Us
1.Our Expertise
2.Quality Products/Services
3.Competitive Pricing
4.Innovation
6.Possibles
7.Authorization by ABB Schneider Siemens